| Waste
Incineration Facility |
| |
|
|
 |
| |
| Project
Name |
Municipal
Waste Incineration Facility |
Project
Aim
|
Waste
Incineration System:
- Alternative solution for
Landfill-related issues
- Improvement of living condition
with cleaner environment |
| Capacity |
1000
ton/day (250 ton/day ¡¿ 4 units) |
| Contract
Plan |
Turn-key:
Design & Construction |
| Construction
Period |
From
contract to within 36 months |
|
|
|
 |
| |
|
| |
|
| |
|
| |
|
| |
|
|
 |
| |
Incineration Solid-Waste Facility |
| |
¨ç Construction & Operating Cost Down |
| |
- Quantity of Machinery reduced
- High Efficiency Machinery
- Energy Saving System
- Low Machinery maintenance
|
| |
¨è Maintenance Effectiveness |
| |
- Machinery designed, arranged, and secured
for repair effectiveness
- Simplification of Facilities
- Secure Conversion of System
|
| |
¨é Neighborhood Residents |
| |
- Environmental pollution is far below Malaysia¡¯s
acceptable standards
- Prevents diffusion of dust into atmosphere
|
| |
¨ê Safety, confidence, and smoothness of operation
of fully automated system |
| |
¨ë Compliance of Equipment |
| |
- International standard: Civil, Electrical,
Mechanical, & Architectural
|
 |
| |
|
|
 |
| |
|
|
 |
| |
|
|
 |
 |
Construction Record |
|
| |
Facility
Name
|
Capacity
( ton/day ) |
Start |
Finish |
Remark |
| Pyung-Chon,
An-Yang Gun |
150 |
1984 |
1986 |
Design
&
Construction |
| Kowang-Myung
City |
200 |
¡¯96.03 |
¡¯98.11 |
¡¨ |
| An-San
City |
400 |
¡¯97.11 |
¡¯01.04 |
¡¨ |
| Bun-dang,
Sung-Nam City |
600 |
¡¯94.12 |
¡¯98.03 |
¡¨ |
| Gang-Nam,
Seoul |
900 |
¡¯96.09 |
¡¯00.11 |
¡¨ |
| Yang-Chon,
Seoul |
550 |
¡¯92.12 |
¡¯96.02 |
¡¨ |
|
| |
|
 |
Design Record |
|
| |
| Client
Name |
Project
Name |
Capacity
( ton/day ) |
| An-Yang
City |
Basic
& Detail Design for Living Waste Incineration
Facility, An-Yang City |
200 |
Korea
Water Resources
Corporation |
Basic
& Detail Design for Living Waste Incineration
Facility, An-San City |
300 |
| Sung-Nam
City |
Basic
& Detail Design for Living Waste Incineration
Facility, Sung-Nam City |
600 |
| Dong-Duchon
City |
Feasibility
Study & Basic Plan for Incineration
Facility, Dong-Duchon City |
100 |
| Dong-Duchon
City |
Feasibility
Study & Basic Design for Landfill Facility,
Dong-Duchon City |
50 |
| Ga-
Pyung Gun |
Basic
& Detail Design for Incineration Facility,
Ga- Pyung Gun |
20 |
| Yong-In
City |
Basic
Design for Incineration Facility, Yong-In
City |
100 |
| Seoul
City |
Supervision
for Incineration Facility, Mok-Dong |
550 |
| Jegu
City |
Supervision
for Incineration Facility, San-Nam &
San-Buk |
300 |
| Yang-Pyung
Gun |
Supervision
for Incineration Facility, Yang-Pyung |
50 |
|
|
 |
| |
|
Exhaust Allowance Value: International Law |
|
| |
| Air
pollution of Kinds |
Unit |
Exhaust Allowance
Value |
Design Basis
Value |
| SOx |
ppm |
300(12)
below |
30 below |
| HCl |
ppm |
50(12) below |
20 below |
| NH3 |
ppm |
100 below |
50 below |
| NOx |
ppm |
200 below |
75 below |
| CS2 |
ppm |
30 below |
10 below |
| CO |
ppm |
600(12)
below |
20 below |
| HCHO |
ppm |
20 below |
7 below |
| F |
ppm |
3 below |
1.5 below |
| H2S |
ppm |
15 below |
7 below |
| Hg |
mg/Sm3 |
5 below |
0.05 below |
| Cd |
mg/Sm3 |
1 below |
0.05 below |
| As |
ppm |
3 below |
0.02 below |
| Pb |
ppm |
5 below |
1.5 below |
| Cr |
mg/Sm3 |
1 below |
0.3 below |
| Cu |
mg/Sm3 |
10 below |
2 below |
| Zn |
mg/Sm3 |
30 below |
0 below |
| Ni |
mg/Sm3 |
20 below |
3 below |
| Smoke |
Degree |
2 below |
0 |
| Dioxin |
ngTEQ/Nm3 |
0.5 below |
0.1 below |
| Cl |
ppm |
60(12)
below |
20 below |
| HCN |
ppm |
10 below |
4 below |
| Br |
ppm |
5 below |
1.5 below |
| Benzene |
ppm |
50 below |
25 below |
| Phenol |
ppm |
10 below |
4 below |
| Odor |
Degree |
2 below |
1 below |
| Dust |
mg/Sm3 |
80(12)
below |
10 below |
| Cr |
mg/Sm3 |
0.5 below |
0.5 below |
|
| |
International Standard
Standard Oxygen Concentration (O2-12%) |
|
 |
| |
| Section |
Korea
(Kor. Won :W) |
U.S.A
(Dollars : $) |
Malaysia
(RM) |
Remark |
| 1. Design Cost |
| 1) Basic
Design |
| 2) Detail
Design |
|
| |
| 3,520,000,000 |
| 4,480,000,000 |
|
| |
| 2,940,685.044 |
| 3,742,690.056 |
|
|
|
| Total |
8,000,000,000 |
6,683,375.100 |
25,000,000 |
5.00
% |
| 2. Construction Cost |
| 2.1) Mechanical
Facility |
| -
Pretreatment |
| -
Incineration |
| -
Combustion gas Treatment |
| -
Electric Generation |
| -
Wastewater Treatment |
| -
Pipe, Duct |
| -
Air Conditioning |
|
| |
| |
| 2,272,000,000 |
| 33,600,000,000 |
| 12,800,800,000 |
| 3,200,000,000 |
| 3,200,000,000 |
| 4,800,000,000 |
| 9,600,000,000 |
|
| |
| |
| 1,898,078.528 |
| 28,070,175.420 |
| 10,693,400.160 |
| 2,673,350.040 |
| 2,673,350.040 |
| 4,010,025.060 |
| 8,020,050.120 |
|
| |
| |
| 7,100,000 |
| 105,000,000 |
| 40,000,000 |
| 10,000,000 |
| 10,000,000 |
| 15,000,000 |
| 30,000,000 |
|
| |
| |
| 1.42
% |
| 21.00
% |
| 8.00
% |
| 2.00
% |
| 2.00
% |
| 3.00
% |
| 6.00
% |
|
| Total |
69,472,000,000 |
58,038,428.370 |
217,100,000 |
43.42
% |
| 2.2) Electric
Facility |
| 2.3) Machinery
Facility |
| 2.4) Engineering
Works |
| 2.5) Construction |
| 2.6) Landscape
Architecture |
| 2.7) Test
Operation & Education |
| 2.8) Management
|
|
| 11,200,000,000 |
| 4,800,000,000 |
| 19,200,000,000 |
| 32,000,000,000 |
| 800,000,000 |
| 3,200,000,000 |
| 4,928,000,000 |
|
| 9,356,725.140 |
| 4,010,025.060 |
| 16,040,100.240 |
| 26,733,500.400 |
| 668,337.510 |
| 2,673,350.040 |
| 4,116,959.062 |
|
| 35,000,000 |
| 15,000,000 |
| 60,000,000 |
| 100,000,000 |
| 2,500,000 |
| 10,000,000 |
| 15,400,000 |
|
| 7.00
% |
| 3.00
% |
| 12.00
% |
| 20.00
% |
| 0.50
% |
| 2.00
% |
| 3.08
% |
|
| Total |
76,128,000,000 |
63,598,997.450 |
237,900,000 |
47.58
% |
| 3.
Supervision Cost |
6,400,000,000 |
5,346,700.080 |
20,000,000 |
4.00
% |
| Grand
Total |
160,000,000,000 |
133,667,502.00 |
500,000,000 |
100.00
% |
|
| |
Optional: Pretreatment Facility
1 RM = W 320.00 (Kor Won)
1 USD = W 1,197.00 (Kor Won)
Go with the exchange rate fluctuation |
|
 |
| |
|
| |
|
|
|
|